What size power station keeps a fridge running through a 24-hour outage?
Our best fit is the PECRON E2400LFP, at about 33 h calculated. The plan needs 1,252 Wh at the outlet over 24 hours and about 1,000 W at start-up, from maker specs and cited appliance figures checked .
Yes. PECRON E2400LFP runs a fridge through a 24-hour outage for about 33 h. calculated from maker specs, .
Links go to the maker's store. RunTimeFit participates in the eBay Partner Network. RunTimeFit may earn a commission from qualifying eBay purchases made through links on this site, at no extra cost to you. Disclosure.
Goal: 24 h. Hours use maker inverter efficiency where published, otherwise the 0.85 estimate, and leave out idle draw the maker doesn't publish. Stations shown out of stock or with availability not shown are skipped. How we pick.
Open this plan in the calculator to change hours, watts, solar or temperature.
Devices and assumptions
| Device | Qty | Hours a day | Running | Starting | Source |
|---|---|---|---|---|---|
| Refrigerator (full-size) | 1 | On the whole time | 275 W | 1,000 W | ENERGY STAR data + Champion chart · cycles about 19% of the time calculated |
Together: 275 W running, about 1,000 W while the largest motor starts, and 1,252 Wh a day. Over the 24-hour goal that is 1,252 Wh at the outlet calculated.
- Full-size fridge energy is the median ENERGY STAR annual figure spread evenly over the day.
- Starting watts are the midpoint of the Champion Power Equipment chart range.
- The fridge stays plugged in the whole outage; opening the door less helps.
Stations that fit, cheapest first
| Station | Hours calculated | Starting headroom | List price |
|---|---|---|---|
| PECRON E1500LFP | 25 h | 77% | $549 |
| PECRON E2400LFP | 33 h | 75% | $649 |
| OUPES Mega 2 | 33 h | 82% | $729 |
| EcoFlow DELTA 3 Max | 33 h | 58% | $899 |
| Jackery Explorer 2000 v2 | 33 h | 77% | $899 |
| PECRON F3000LFP | 50 h | 78% | $899 |
| Jackery Explorer 1500 v2 | 25 h | 75% | $949 |
| Anker SOLIX C2000 Gen 2 | 33 h | 75% | $999.99 |
22 of 43 stations in our data fit, counting out-of-stock and unpriced ones; this table shows the cheapest in-stock ones.
What would change this answer
- Your own device watts: the label on the device beats any typical figure. Enter it in the calculator.
- Inverter idle draw: most makers don't publish it, so hours here leave it out. Small loads feel this most.
- Cold: below a maker's temperature range a station may stop discharging or charging.
Our take
A full-size fridge is mostly a starting-watts problem, not a battery-size problem: the compressor's start is several times its running draw, so check surge first. After that, the daily energy of a modern ENERGY STAR fridge is modest, which is why mid-size stations cover a day. Older fridges can use far more, so read the yearly kWh on your fridge's yellow EnergyGuide label and enter your own watts in the calculator.
Related
- What size power station do you need for a power outage
- What size power station keeps a chest freezer cold for 48 hours
- What size power station runs a sump pump through a 12-hour storm
- What size power station keeps a home office running for an 8-hour outage
- What size power station runs a CPAP for 3 nights of camping
- What size power station runs a travel CPAP without a humidifier for 2 nights
- What size power station runs Starlink, a laptop and a fridge for a day of van life
- How the hours are calculated