Skip to content
RtRunTimeFit

Appliance runtime

How long can a power station run a window air conditioner?

A 1,000 Wh station runs a window ac for about 1.6 h calculated, at 525 W running and 1,050 W starting (Champion wattage chart). Our best fit for a 5,000 BTU window AC for one hour is the Jackery Explorer 1000 v2, at about 1.7 h. Maker specs checked .

Yes. Jackery Explorer 1000 v2 runs a 5,000 BTU window AC for one hour for about 1.7 h. calculated from maker specs, .

Links go to the maker's store. RunTimeFit participates in the eBay Partner Network. RunTimeFit may earn a commission from qualifying eBay purchases made through links on this site, at no extra cost to you. Disclosure.

Best fit
Jackery Explorer 1000 v2
About 1.7 h calculated
1,070 Wh LiFePO4 · 1,500 W continuous
Starting headroom 65%
$499 list price, checked · In stock
5-year warranty · 10.8 kg
Cheapest in-stock station with at least 20% spare runtime, a published warranty of at least two years and a published surge rating.
Check price for Jackery Explorer 1000 v2
Budget pick: the best fit is already the cheapest in-stock station that works.
More headroom
PECRON E1500LFP
About 2.5 h calculated
1,536 Wh LiFePO4 · 2,200 W continuous
Starting headroom 76%
$549 list price, checked · In stock
5-year warranty · 17.4 kg
Cheapest station that works in the next size class up (1,500–1,999 Wh).
Check price for PECRON E1500LFP

Goal: 1 h. Hours use maker inverter efficiency where published, otherwise the 0.85 estimate, and leave out idle draw the maker doesn't publish. Stations shown out of stock or with availability not shown are skipped. How we pick.

Hours by station size

Hours by rated capacity
Rated capacityWindow AC (5,000 BTU), compressor running continuously calculatedWindow AC (10,000 BTU), compressor running continuously calculated
500 Wh0.8 h0.4 h
1,000 Wh1.6 h0.8 h
2,000 Wh3.2 h1.6 h
3,000 Wh4.9 h2.4 h
5,000 Wh8.1 h4.0 h

A generic station of that rated size at the 0.85 default efficiency with no idle draw, assuming its watts are enough to run and start the load. Real stations are below.

Running and starting watts

  • Window AC (5,000 BTU), compressor running continuously: 525 W running, 1,050 W starting, 12,600 Wh a day (Champion wattage chart). Typical running W is the midpoint of the chart's 450–600W range.
  • Window AC (10,000 BTU), compressor running continuously: 1,050 W running, 2,100 W starting, 25,200 Wh a day (Champion wattage chart). Typical running W is the midpoint of the chart's 900–1,200W range.

These hours assume the compressor never cycles off, so a thermostat that cycles it gives more hours.

Every in-stock station we cover

Hours on each station
StationCapacityWindow AC (5,000 BTU), compressor running continuously calculatedWindow AC (10,000 BTU), compressor running continuously calculated
Goal Zero Yeti 500499.2 WhToo much powerToo much power
OUPES Exodus 700576 Wh0.9 hToo much power
Goal Zero Yeti 700677.37 WhWon't start itToo much power
Anker SOLIX C1000 Gen 21,024 Wh1.7 h0.8 h
BLUETTI Elite 100 V21,024 Wh1.7 hWon't start it
EcoFlow DELTA 31,024 Wh1.7 h0.8 h
EcoFlow DELTA 3 Classic1,024 Wh1.7 hWon't start it
EcoFlow DELTA 3 Plus1,024 Wh1.7 h0.8 h
OUPES Mega 11,024 Wh1.7 h0.8 h
Jackery Explorer 1000 v21,070 Wh1.7 h0.9 h
BLUETTI AC1801,152 Wh1.6 h0.8 h
Jackery Explorer 1000 Plus1,264.64 Wh2.0 h1.0 h
Goal Zero Yeti 1500 (2026)1,505.28 Wh2.4 h1.2 h
Jackery Explorer 1500 Ultra1,536 Wh2.5 h1.2 h
Jackery Explorer 1500 v21,536 Wh2.5 h1.2 h
PECRON E1500LFP1,536 Wh2.5 h1.2 h
Jackery Explorer 2000 v22,042 Wh3.3 h1.7 h
Anker SOLIX C2000 Gen 22,048 Wh3.3 h1.7 h
EcoFlow DELTA 2 Max2,048 Wh3.3 h1.7 h
EcoFlow DELTA 3 Max2,048 Wh3.3 h1.7 h
EcoFlow DELTA 3 Max Plus2,048 Wh3.3 h1.7 h
OUPES Mega 22,048 Wh3.3 h1.7 h
PECRON E2400LFP2,048 Wh3.3 h1.7 h
Anker SOLIX F30003,072 Wh5.0 h2.5 h
EcoFlow DELTA 3 Ultra3,072 Wh5.0 h2.5 h
PECRON F3000LFP3,072 Wh5.0 h2.5 h
Anker SOLIX F3800 Plus3,840 Wh6.2 h3.1 h
Goal Zero Yeti PRO 40003,993.6 Wh6.5 h3.2 h
EcoFlow DELTA Pro 34,096 Wh6.6 h3.3 h

Shown in stock at the maker store, with a maker list price. "Won't start it" means the starting watts exceed the surge rating (or the continuous rating where no surge rating is published).

Sources